RidgescanAI

AScope, standard and summary

Property1247 Redwing Lane, Eagle, ID 83616 (sample)
Details2,410 sq ft · two-story · crawlspace · built 2011 · well & septic
InspectionSample date · report delivered the same day
StandardRidgescan Standard v1: every item in the InterNACHI Residential Standards of Practice, plus instrument readings, a thermal sweep, 360° views and crawlspace rover coverage · Idaho
Captured byRidgescan inspector, full-service capture
Reviewed & signedCertified home inspector (InterNACHI CPI)
Completeness48 of 48 required items captured · verified before release
Report version1 · signed
Drone roof imagingThermal imagingCrawlspace rover360° every roomRecorded tests
Scope statementThis report documents a non-invasive, visual and instrument-assisted examination of the readily accessible systems and components of the property on the date of inspection, performed to the Ridgescan Standard. All ten SoP sections were inspected and coverage was verified complete before release. Items marked Beyond SoP are enhancements (thermal imaging, instrument readings) that exceed the standard visual scope. Findings are referred to the appropriate licensed trade; a referral is a recommendation, not a finding of defect. The seller authorized this capture and agreed to the Ridgescan Terms before it began.
2Safety
3Major
4Maintenance
4Monitor

BYour home at a glance

This 2011-built, roughly 2,400 sq ft home in Eagle is in generally good condition for its age. The major systems operated normally and no structural concerns were observed. The items that most deserve attention before closing fall into three groups.

Two quick safety corrections

A kitchen GFCI that didn't trip on test, and a deck ledger with no visible flashing. Both are low-cost, and both go to a licensed trade.

Three larger items worth negotiating

The roof is showing its age, a bath fan vents into the attic, and we measured elevated moisture behind the guest bath wall. Moisture is far cheaper to resolve before closing than after.

Budget items, not emergencies

The water heater is at nine years and water pressure sits just under the limit. Plan for them; they don't need action this week.

Everything is detailed by system in section D, with the photos, thermal frames, rover stills and 360° views behind each finding. The repair-priority matrix on the next page sorts every finding by urgency so you and your agent can decide what to act on.

CRepair-priority matrix

Every finding, sorted by urgency. Ranges are budgetary, for planning only; they are not bids. Get written quotes from registered contractors, or ask us for repair cost quotes through an independent registered general contractor (Ridgescan takes no fee from the contractor).

PriorityFindingRecommendationBudgetary range
SafetyKitchen counter GFCI did not trip on testKitchen · §3.7Replace the GFCI deviceLicensed electrician$120–250
SafetyDeck ledger: no visible flashing, attachment not confirmedRear deck · §3.2Evaluate attachment; add ledger flashingRegistered general contractor$400–1,500
MajorGranule loss (south slope) and lifted shingle at NE ridgeRoof · §3.1Seal the ridge defect now; budget for re-roof within 0–5 yearsRoofing contractor$250–600 now · $12,000–22,000 re-roof
MajorBath exhaust fan venting into the atticAttic above primary bath · §3.9Re-vent to the exteriorHVAC technician$300–600
MajorElevated moisture and thermal anomalyGuest bath wall · §3.6Evaluate for an active leak before closeLicensed plumber$500–3,000
Maint.Negative grading at the NE cornerExterior · §3.2Re-grade to slope away 6" over 10'; extend downspoutRegistered general contractor$300–1,200
Maint.Lifted chimney step flashing; cracked vent bootRoof · §3.1Re-seal flashing; replace bootRoofing contractor$200–500
Maint.Vapor barrier gap at the SE cornerCrawlspace · §3.3Extend the vapor barrier to full coverageRegistered general contractor$150–400
Maint.Drip at the angle stop under the kitchen sinkKitchen · §3.6Replace the shut-off valveLicensed plumber$120–250
MonitorWater heater at 9 yearsGarage · §3.6Budget for replacementLicensed plumber, when replaced$1,500–2,800
MonitorStatic water pressure 78 psi (limit 80)Hose bib · §3.6Monitor; add a pressure-reducing valve if it risesLicensed plumber$350–700 if needed
MonitorFogged glass, one living-room windowLiving room · §3.10Replace the sealed unit as desiredRegistered general contractor$400–900
MonitorCold spot on NE bedroom ceiling: insulation deficit, dryAttic · §3.9Top up attic insulation over the NE bedroomRegistered general contractor$300–800

DSystems, item by item

Condition codes: IN inspected, no material defect · D deficiency observed · NI not inspected, limitation noted · NP not present. Evidence tiles below are illustrations; a live report shows the actual photos, thermal frames, rover stills and 360° views, each tied to its item.

3.1Roof

DRoof coveringsINGutters, downspouts & drainageDVents, flashing & penetrationsINRoof structure from attic

DescribedComposition asphalt shingle, gable, approximately 14 years old, one layer. Inspected by drone from all four elevations and from the attic.

Major

Granule loss on the south slope; lifted shingle at the NE ridge

ObservationAerial imaging shows two zones of granule loss on the south slope and one lifted shingle at the northeast ridge, a near-term path for water.
ImplicationFunctional today, but the ridge defect can admit water in the next storm, and the field is in the last third of a typical service life.
RecommendationSeal the ridge defect now. Budget for replacement within 0–5 years. Service-life estimate is Beyond SoP.
Referred to a roofing contractor
Maint.

Lifted step flashing at the chimney; cracked neoprene vent boot

ObservationStep flashing at the chimney base has lifted along the uphill edge. One plumbing vent boot is cracked at the collar.
RecommendationRe-seal the flashing and replace the boot to prevent water intrusion.
Referred to a roofing contractor

Gutters, downspouts and drainage: inspected; downspouts discharge to grade on all four sides; no material defects observed. Roof structure from the attic: no staining or daylight observed on the roof deck.

3.2Exterior

INWall covering, flashing & trimINEaves, soffits & fasciaINExterior doorsINRepresentative windowsDDecks, porches & railingsDGrading & drainageINWalkways & driveways

DescribedFiber-cement siding, concrete walks and driveway, attached rear deck. Both exterior doors operated, latched and locked.

Safety

Deck ledger has no visible flashing; attachment not confirmed

ObservationThe ledger board at the house has no visible flashing, and the fastening pattern could not be confirmed from below. Guard height 37" and baluster spacing under 4" are within norms.
ImplicationImproperly attached ledgers are a recognized collapse hazard, and an unflashed ledger traps water against the house.
RecommendationHave the attachment evaluated and ledger flashing added.
Referred to a registered general contractor
3 5/8 in
Maint.

Negative grading at the northeast corner

ObservationSoil slopes toward the foundation at the NE corner, directing surface water at the wall. This correlates with the crawlspace observation in §3.3.
RecommendationRe-grade to slope away 6" over 10' and extend the downspout discharge.
Referred to a registered general contractor
360°

3.3Basement, foundation & crawlspace

INFoundationNPBasementDCrawlspaceINStructural componentsINWater intrusion & wood-soil contact

DescribedPerimeter stem-wall foundation with a vented crawlspace; dimensional-lumber floor framing. Access via the exterior hatch on the north elevation. The rover surveyed the full sub-floor without disturbing the space.

Maint.

Vapor barrier gap at the SE corner; historic moisture staining on one joist

ObservationVapor barrier covers about 90% of the soil with a gap at the SE corner. One joist near the NE corner shows historic moisture staining; the moisture reading is at the elevated-dry boundary. No standing water. Minor efflorescence on the north stem wall.
RecommendationExtend the vapor barrier to full coverage, correct the §3.2 grading, and monitor the flagged joist. No indication of foundation movement observed.
Referred to a registered general contractor
R1 · 11:02:14
R1 · 11:04:5116% MC
Beyond SoP · readingsJoist moisture (NE) 16% MC · dry <15 · elevated 15–20 · wet >20Vapor barrier coverage ~90%Standing water none

3.4 · 3.5Heating & cooling

INHeating operationINThermostat, energy source & methodINHeating distributionINCooling operationINThermostat & cooling methodINCooling distribution

DescribedGas forced-air furnace with a split-system air conditioner; thermostat in the main hall; ducted distribution in the crawlspace and attic. Both responded to normal controls.

Operated normally. Filter due for replacement; recommend routine service. The heat exchanger interior is outside the SoP and was not inspected.

Beyond SoP · readingsCooling supply/return split 17.8°F · 14–22 typicalAmbient CO at the furnace 0 ppmCondensate line clear

3.6Plumbing

INMain water & fuel shut-offsINWater heater, venting & TPR valveDSupply, fixtures & faucetsINFunctional flow & drainageINToiletsINDrain, waste & ventNPSump & ejector pumpsDActive leaks

DescribedPrivate well supply; PEX distribution; 40-gallon gas water heater, 9 years old, TPR valve and discharge line present and correctly routed, seismic straps present. Main water shut-off at the crawlspace access; gas shut-off at the meter. Well and septic are outside the SoP and reported separately.

Major

Elevated moisture and a thermal anomaly at the guest bath wall

ObservationAfter running water in the guest bath, the thermal camera showed a cool anomaly at the base of the wall behind the tub, and a moisture reading at the same spot came back wet. No visible staining yet.
ImplicationConsistent with an active leak at the tub drain or supply. Moisture behind a wall is far cheaper to resolve before closing than after.
RecommendationEvaluate for an active leak before close.
Referred to a licensed plumber
Δ −4.1°F
22% MC
Maint.

Drip at the angle stop under the kitchen sink

ObservationSlow drip at the cold-water shut-off valve under the kitchen sink; cabinet floor dry.
RecommendationReplace the shut-off valve.
Referred to a licensed plumber
Beyond SoP · readingsStatic water pressure 78 psi · >80 requires a PRV · monitorTwo-fixture flow no noticeable dropHot on the left at all faucets yesWater heater 9 yr · TPR present · straps present

3.7Electrical

INService drop, mast, meter & entranceINMain disconnect & panelboardsINOvercurrent devices, grounding & bondingINSwitches, fixtures & receptaclesDGFCI & AFCI testingINSmoke & CO detectorsINBranch wiring type

Described200 A overhead service; copper branch wiring; labeled panel with no open slots, no double-taps. Smoke and CO detectors present on both levels.

Safety

Kitchen counter GFCI did not trip on test

ObservationThe GFCI protecting the kitchen counter receptacles did not trip when tested with a GFCI tester. All other GFCI devices tripped; bedroom AFCI tested with its test button and tripped.
ImplicationLoss of shock protection at the counters. Safety-classified because of the failure mode, not the cost.
RecommendationReplace the GFCI device.
Referred to a licensed electrician
no trip
normal
Recorded testsGFCI devices tested 6 · 1 did not trip (kitchen)AFCI devices tested 2 · passReceptacles tested (plug-in tester) 18 · no open grounds · no reversed polarity

3.8Fireplace

INFireplace & chimney, visible portionsINLintels, dampers & cleanout doors

DescribedOne gas-log fireplace in the family room; masonry chimney. Damper opened and closed; hearth extension adequate; smoke and CO detectors present in the same room. The flue interior is outside the SoP and was not inspected.

Inspected; no material defects observed.

3.9Attic, insulation & ventilation

DInsulation in unfinished spacesINVentilation of unfinished spacesDKitchen, bath & laundry exhaust

DescribedBlown fiberglass, approximately 12" average depth; ridge and soffit ventilation. Attic entered from the hall hatch.

Major

Primary bath exhaust fan vents into the attic

ObservationThe flex duct from the primary bath fan lies loose on the insulation; it is not connected to a roof or wall cap. The fan runs.
ImplicationWarm, moist air is discharged into the attic, a common source of condensation and mold on the roof deck.
RecommendationRe-vent the fan to the exterior.
Referred to an HVAC technician
360°
Monitor

Cold spot on the NE bedroom ceiling: insulation deficit, not moisture

ObservationThermal imaging shows a cold anomaly on the NE bedroom ceiling. A moisture reading at the same spot came back dry, so the signature is missing or displaced insulation, not water. Pairing thermal with a moisture meter is what tells the two apart.
RecommendationTop up attic insulation over the NE bedroom. A comfort and energy item, not a defect.
Referred to a registered general contractor
Δ 6.2°F
12 in

3.10Doors, windows & interior

DRepresentative doors & windowsINFloors, walls & ceilingsINStairs, steps & landingsINRailings, guards & handrailsINGarage door, opener & safety reverse

DescribedVinyl double-hung windows; sectional garage door with opener. Photo-eye safety sensors reversed the door when the beam was interrupted. Interior guard baluster spacing under 4"; handrail graspable.

Monitor

Fogged glass in one living-room window

ObservationOne sealed glass unit in the living room shows fogging between the panes, indicating a failed seal. Representative doors and windows otherwise operated normally.
RecommendationReplace the sealed unit as desired; a comfort and appearance item.
Referred to a registered general contractor
360°

EAgent repair-request summary

Safety and major items with location and requested action, ready to lift into an addendum. What to request is the buyer's and agent's call; this list is the evidence, not the negotiation.

ItemLocationRequested actionEvidence
Safety GFCI did not tripKitchen counterReplace the GFCI device; licensed electricianPhoto, test result
Safety Deck ledger unflashedRear deckEvaluate attachment and add flashing; registered general contractorPhotos
Major Roof: lifted ridge shingle, granule lossRoof, south slope and NE ridgeSeal ridge defect; roofer's evaluation of remaining lifeDrone frames
Major Bath fan vents into atticAttic above primary bathRe-vent to the exterior; HVAC technicianPhoto, 360°
Major Moisture behind guest bath wallGuest bathPlumber's evaluation for an active leak; repair as foundThermal frame, moisture reading

A re-inspection after repairs is available; contact us to schedule.

FSign-off, scope and limitations

Reviewed and signed by
Certified home inspector

InterNACHI CPI · certification number on file · sample

Signed: sample date, 4:52 PM · report version 1

Capture record

Captured by a Ridgescan inspector. Seller authorization and agreement to the Ridgescan Terms recorded in the app before capture began. 48 of 48 required items present; completeness verified by software before review. Every photo, thermal frame, rover still and 360° is stored with a fingerprint and tied to the item it covers.

A home inspection is a non-invasive, visual and instrument-assisted examination of readily accessible systems and components on the date of inspection, per the Ridgescan Standard. It is not technically exhaustive, not a warranty, and will not identify concealed or latent defects. The inspection does not determine service-life expectancy, insurability, market value or code compliance; items marked Beyond SoP are enhancements outside the standard visual scope. Thermal imaging shows temperature differences at the surface and does not see through materials; a thermal finding is an indicator that warrants confirmation, not a diagnosis. Findings marked Monitor are not defects requiring immediate action. Well, septic and radon, where ordered, are reported separately. Idaho doesn't require home inspectors to be licensed; this report is reviewed and signed by a certified home inspector. Governed by the signed pre-inspection agreement and the Ridgescan Terms and scope.

This is a sample. The property, readings and findings are representative and do not describe a real inspection.