A thermal camera doesn't see heat inside a wall. It sees the temperature of the surface in front of it. Everything a thermal image can tell you about a house follows from that one fact.

How it works

Every surface gives off infrared energy in proportion to its temperature. A thermal camera reads that energy and paints it as a picture: warmer areas one color, cooler areas another. A radiometric camera, which is what Ridgescan carries, goes a step further and stores a temperature value for every pixel in the frame. That matters at review time. The inspector can put a cursor on a suspect patch and read the number, compare it to the wall beside it, and decide whether the difference is meaningful or just the sun on the siding an hour ago.

The image is only as good as the conditions. Thermal needs a temperature difference to work with. Inside versus outside, a running furnace or air conditioner, a wall that was rained on this morning: those create contrast. A mild day with the HVAC off and the house sitting at the outdoor temperature hides a great deal. The inspector records conditions at the time of capture for that reason, and a wall that reads uniformly on a mild day is not the same as a wall with nothing behind it.

What it finds

Moisture

Wet drywall is cooler than dry drywall around it, because water evaporates from the surface and evaporation takes heat. On a thermal frame a leak under a window or at a shower wall shows as a cool patch that often tracks downward from its source. This is the single most valuable thing thermal does in a house, and it is why Ridgescan images every wall and ceiling, not just the ones that look suspicious. Many of the leaks that matter have no stain yet.

A cool patch is not a diagnosis. Every thermal anomaly that looks like moisture is checked with a moisture meter at the surface, and the reading is reported next to the frame. The two together are far stronger than either alone.

Missing or settled insulation

Insulation slows heat moving through a wall or ceiling. Where a bay is empty or the batt has slumped, the surface runs closer to the outdoor temperature than the bays around it, and the stripe follows the framing. Attic insulation that has been pushed aside around a can light or a bath fan shows the same way from the ceiling below.

Air leakage

Outdoor air coming through a gap around a window, a top plate, an electrical box or a door sweep cools or warms the surface in a fan shape spreading from the gap. On a cold day with the house heated, these show clearly.

Electrical heat

At the panel, a breaker or a lug carrying more current than its neighbors runs warmer. A loose connection runs warmer still. A hot spot at the panel is a finding for a licensed electrician, with the frame and the temperature attached. It is also one of the few places thermal catches something no visual inspection would.

Heating and cooling delivery

With the system running, a thermal pass across supply registers shows which rooms are getting air and which aren't, and a radiant floor lights up where the loops are, and stays dark where they've failed.

What it can't do

  • See through walls. Thermal reads the surface. It doesn't show pipes, wiring, framing or a vapor barrier. It shows their effect on surface temperature when there is one, which is often, but not always.
  • Identify mold. It can point at an area that is wet or has been wet. What's growing there, if anything, takes a sample and a lab.
  • Tell you why something is wet. A cool patch under a window could be a flashing failure, a condensation problem, a plumbing leak behind the wall, or last night's rain through an open window. The right trade opens it up and finds out.
  • Find a problem with no temperature signature. A dry rot pocket that's at room temperature is invisible to thermal. So is a crack. Thermal adds to a visual inspection rather than standing in for one.
  • Read shiny surfaces honestly. Bare metal, glass and glossy tile reflect infrared the way a mirror reflects light. A cold spot on a metal duct may be the reflection of the inspector. Radiometric data and an experienced reviewer sort this out; a quick phone-camera attachment usually doesn't.

How to read a thermal finding in a Ridgescan report

A thermal finding is labeled Beyond SoP, because thermal imaging is outside the visual scope of the InterNACHI Standards of Practice the Ridgescan Standard builds on. Each one includes the thermal frame, a visible-light photo of the same spot, the temperature difference the inspector measured, the moisture-meter reading where moisture is suspected, a plain-language note on what the pattern is consistent with, and a referral to a specific trade: plumber, roofer, electrician, HVAC technician or insulation contractor.

The wording is deliberate. The report will say a pattern is consistent with moisture, not that the wall is leaking. That isn't hedging. It's the honest limit of the instrument, and it's why a thermal finding warrants confirmation by the trade rather than a repair request written straight from the image. The frame and the reading give that trade a much better place to start than "have it looked at."